Line 1: |
MEMBCONC |
|
Next n lines: |
Case,Mem,Sl,Ax,Un,Ps,Fx,Fy,Fz,Mx,My,Mz,Cat, Gen1,MInc,Gen2,SInc,PInc |
|
|
|
|
Case |
Load case number |
(Integer) |
Mem |
Member number |
(Integer) |
Sl |
Sub load number |
(Integer) |
Ax |
Axes system (L/G) |
(1 Char) |
Un |
Units system (A/%) |
(1 Char) |
Ps |
Load position |
(Real) |
Fx |
X force |
(Real) |
Fy |
Y force |
(Real) |
Fz |
Z force |
(Real) |
Mx |
X moment |
(Real) |
My |
Y moment |
(Real) |
Mz |
Z moment |
(Real) |
Cat |
Load category |
(Integer) |
Gen1 |
# of loaded members to be generated |
(Integer) |
MInc |
Member number increment |
(Integer) |
Gen2 |
# of loads per member to be generated |
(Integer) |
SInc |
Sub load number increment |
(Integer) |
PInc |
Load position increment |
(Real) |
Ax choices are "L"=Local or "G"=Global.
Un choices are "A"=Actual or "%"=Percentage.
See also Member Concentrated Load Data.