Member concentrated loads text

 

Line 1:

MEMBCONC

 

Next n lines:

Case,Mem,Sl,Ax,Un,Ps,Fx,Fy,Fz,Mx,My,Mz,Cat, Gen1,MInc,Gen2,SInc,PInc

 

 

 

 

Case

Load case number

(Integer)

Mem

Member number

(Integer)

Sl

Sub load number

(Integer)

Ax

Axes system (L/G)

(1 Char)

Un

Units system (A/%)

(1 Char)

Ps

Load position

(Real)

Fx

X force

(Real)

Fy

Y force

(Real)

Fz

Z force

(Real)

Mx

X moment

(Real)

My

Y moment

(Real)

Mz

Z moment

(Real)

Cat

Load category

(Integer)

Gen1

# of loaded members to be generated

(Integer)

MInc

Member number increment

(Integer)

Gen2

# of loads per member to be generated

(Integer)

SInc

Sub load number increment

(Integer)

PInc

Load position increment

(Real)

 

Ax choices are "L"=Local or  "G"=Global.

 

Un choices are "A"=Actual or "%"=Percentage.

 

See also Member Concentrated Load Data.